USB Oscilloscoop – Hantek 6022BE
Hantek 6022BE PC-Based USB Digital Storage Oscilloscope
2 Channels 20MHz 48MSa/s
Informatie (ENG)
Specificaties:
- Cost-effectiveness; Excellent industrial design-the same anodised aluminium casing as iPad, which is not only beautiful and tasteful but also greatly enhanced the hardness of aluminum alloy surface, and has good heat resistance and strong wearability.
- Standard USBXITM interface, easyly inserts into USBXITM housing to make up a combination instrument.
- USB2.0 interface, no external power source required, easy to use.
- Be suitable for notebook computer, product line maintenance,be used easily on business.
- Dimensions (mm):205(L) x120(W) x35(H), be carried easily.
- High performance, 48MS/s real-time sampling, 20MHz Bandwidth,
- Operating System: Windows 7, Windows NT, Windows XP,VISTA.
- 23 measurement functions, PASS/FAIL Check, be suitable for technical application>
- Waveform average, persistence, intensity,invert,addition, subtraction, multiplication, division,X-Y plot.
- Save waveform in the following: text file, jpg/bmp graphic file, MS excel/word file.
- FFT
- One computer can connect many DSO, extend channel easily.
- Labview\VB\VC\Delphi\C++Builder Second Design instance.
Hardware specificaties:
Channel |
2 Channels |
Bandwidth |
20MHz |
Input Impandence |
1MO 25pF |
Max. Sample rate |
48MS/s |
Vertical resolution |
8Bit |
Gain range |
20mV-5V, 8Steps |
DC accuracy |
±3% |
Timebase range |
1ns-9000s, 39 Steps |
Vertical adjustable |
Yes |
Input protection |
Diode clamping |
X-Y |
Yes |
Trigger Mode |
Auto, Normal and Single |
Trigger Slope |
+/- |
Trigger level adjustable |
Yes |
Trigger Type |
Rising edge, falling edge |
Trigger Source |
CH1, CH2 |
Pre/Post trigger |
0-100% |
Sampling selection |
Yes |
Waveform Display |
port/line, waveform average, persistence, intensity |
Network |
Open/Close |
Vertical mode |
CH1, CH2, Dual, ADD |
Cursor measurement |
Yes |
Math |
FFT, addition, subtraction, multiplication, division. |
Cursor |
Frequency, Voltage |
Accessories |
S/W CD, probes, manual, USB cord |
Foto’s:
Software:
Screens:
Windows 8 drivers installeren
Windows 8 driver zijn te installeren via het apparaatbeheer, zo de volgende screens:
Open6022be
1 2 3 4 5 6 7 8 9 10 |
Limitations: ----------------------------------------------------------- 1. Trigger only works in Auto. 2. Horizontal mode limited to YT only. 3. Cannot Stop & Start Waveform (Acquire controls non-functional) 4. No Importing & Exporting waveforms or waveform images (not implemented). 5. Reference channel non functional (due to no importing) 6. Toolbar Buttons & Features incomplete. 7. Some Main Menu items incomplete or non functional. 8. GUI Control settings not saved on application close or restored on startup. |
[#/drivers/usb_oscilloscoop_hantek_6022be” ]