ESP8266 WiFi – CO2 sensor T6613 (ArduinoIDE)

Espressif logo

arduino logo

Hardware

Informatie (ENG)

The T6613 is a CO2 Module designed to meet the volume and delivery expectations of Original Equipment Manufacturers (OEMs). The module is ideal for customers who are familiar with the design, integration and handling of electronic components. All units are factory calibrated to measure CO2 concentration levels up to 2000ppm.
  • Flexible CO2 sensor platform designed to interact with other microprocessor devices
  • Eliminates the need for calibration with Telaire’s patented ABC Logic™ software
  • Lifetime calibration warranty
  • 0 to 2000ppm Measurement range
  • 400 to 1250ppm ± 30ppm or 3% of Reading accuracy
  • UART at 19200baud digital output
  • 0 to 4VDC Analogue output
  • 0.9W Peak power consumption
  • Interface connections designed for 12-pin male header with 0.1in (2.54mm) spacing

Specs (ENG)

Method Non Dispersive Infrared (NDIR), gold-plated optics, diffusion or flow through sampling (with Telaire’s patented ABC Logic Self Calibrated Algorithm)
Measurement Range 0 to 2000 ppm**
Dimensions 2.25 in X 1.365 in X 0.60 in
(57.15 mm X 34.67 mm X 15.24 mm)
Accuracy*
  • 400-1250 ppm ± 30 ppm or 3% of reading, whichever is greater
  • 1250-2000 ppm ± 5% of reading + 30ppm
Temperature Dependence 0.2% FS per °C
Stability < 2% of FS over life of sensor (15 years typical)
Pressure Dependence 0.13% of reading per mm Hg
Calibration Interval Not required
Response Time < 2 minutes for 90% step change typical
Signal Update Every 4 seconds
Warm Up Time
  • < 2 minutes (operational)
  • 10 minutes (maximum accuracy)
Operating Conditions
  • 32°F to 122°F (0°C to 50°C)
  • 0 to 95% RH, non-condensing
Storage Conditions -40°F to 158°F (-40°C to 70°C)
Output
Digital UART @ 19200 Baud (Please call for detailed product specifications.)
Analog 0 to 4 VDC
Power Supply Requirements 5 VDC regulated (±5%)
Power Consumption
  • 0.90 watts peak
  • 0.165 watts average
Interface Connections Designed for 12 pin male header with 0.1 in (2.54 mm) spacing. Header not included.
Flow Rates (Via Flow Ports) Flow through version 40 to 50 cc/min

Pinout


Maten


Aansluiten op de Arduino (RX/TX met SoftwareSerial)

Sluit de module aan op de Arduino volgens onderstaand overzicht:

Ps. je hebt een externe voeding nodig om de CO2 sensor te voeden!

T6613 pin:ESP pin:Externe voeding:
RX2
TX0
4 - GNDGNDGND
5 - VCC (5v)VCC (5v)

Het resultaat